True-RMS Digital Multimeter 179 Fluke

Multimeter 289 fluke

True Rms Multimeter 117 Fluke

Ingco DM200 Digital Multimeter


Digital Multimeter INGCO DM7504
GZ Industrial Supplies is the distributor and supplier of Fluke measuring equipment and other industrial tools in Nigeria. The Digital Multimeter 87v Fluke uses its low pass filter function to measure voltage and frequency accurately on electrically "noisy equipment like adjustable speed motor drives.
Our Digital Multimeter 87v Fluke uses the peak capture function to detect intermittent problems and transients as fast as 250 microseconds (µs) and the input alert function gives you an audible warning against wrong use of input jacks. The Digital Multimeter 87v Fluke multimeters are independently tested for use in CAT IV 600V/CAT III 1000V environments which can also withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.
Electrical Specifications |
||
DC Voltage |
Range |
0.1 mV to 1000 V |
Accuracy |
±(0.05% + 1) |
|
Maximum resolution |
0.1 mV |
|
AC Voltage |
Range |
0.1 mV to 1000 V |
Accuracy |
±(0.7% + 4) true-rms |
|
AC bandwidth |
20 kHz with low pass filter; 3 dB @ 1 kHz |
|
Maximum resolution |
0.1 mV |
|
DC Current |
Range |
0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy |
±(0.2% + 2) |
|
Maximum resolution |
0.1 µA |
|
AC Current |
Range |
0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy |
±(1.0% + 2) true-rms |
|
Maximum resolution |
0.1 µA |
|
Resistance |
Range |
0.1 Ω to 50 MΩ |
Accuracy |
±(0.2% + 1) |
|
Maximum resolution |
0.1 Ω |
|
Capacitance |
Range |
0.01 nF to 9999 μF |
Accuracy |
±(1% + 2) |
|
Maximum resolution |
0.01 nF |
|
Frequency |
Range |
0.5 Hz to 199.99 kHz |
Accuracy |
±(0.005% + 1) |
|
Maximum resolution |
0.01 Hz |
|
Duty cycle |
Maximum duty cycle |
99.9% |
Accuracy |
±(0.2% per kHz + 0.1%) |
|
Maximum resolution |
0.1% |
|
Temperature measurement range |
–200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe |
|
80 BK temperature probe |
–40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater |
|
Conductance |
Maximum conductance |
60.00 nS |
Accuracy |
±(1.0% + 10) |
|
Maximum resolution |
0.01 nS |
|
Diode test |
Range |
2 V |
Resolution |
0.001V |
|
Accuracy |
±(1% + 1) |
|
Diagnostics and data storage |
Peak Min/Max |
250 μS |
Min/Max/Avg |
Yes |
|
Reading hold/Auto (Touch) Hold |
Yes |
|
Relative reference |
Yes |
|
Display |
Digital |
6000 counts updates 4/second 19,999 counts in high–resolution mode |
Analog bar graph |
32 segments, updates 40/second |
|
Backlight |
Two level |
|
Low pass filter (VFD measurements) |
Yes |
|
Input Alert™ |
Yes |
Contact us for product availability in your region.