UPS Quantum XL 1-3KVA Tescom

2 reviews(2) Write a Review
Ask Questions

UPS Quantum XL 1-3KVA Tescom

₦0.00
  • SKU: Tescom XL 1-3KVA
  • MPN: Tescom XL 1-3KVA
  • Weight: 8.00 KGS
  • Shipping: Calculated at Checkout
In Stock & Ready To Ship!
Current Stock:Only left:

Frequently Bought Together:

Total: Inc. Tax
Total: Ex. Tax
Description

UPS Quantum XL 1-3KVA Tescom

GZ Industrial Supplies is the distributor of TESCOM Power Protection Products in Nigeria. The UPS Quantum XL 1-3KVA Tescom is most cost-effective solution with outstanding performance.

Our UPS Quantum 6-10KVA Tescom is ready to meet the most challenging power conditions. It comes with On-line topology, Pure sinewave output, Graphic LCD display and it is CE Compliant.

 

Features of UPS Quantum XL 1-3KVA Tescom

 

• DSP control
• 0.9 Output power factor
• Wide input range
• High efficiency mode (ECO)
• Frequency converter mode
• Input THDI < 5%
• Output voltage regulation < 2%
• Output THDv < 3%
• Auto self-testing system
• Fan speed control
• Extendable run time
• Power management software
• Multiple communication ports
• Optional SNMP & Relay Cards
• Compact design

 

 

MODEL
QUANTUM 1000XL
QUANTUM 2000XL
QUANTUM 3000XL
Capacity (VA/W)
1000VA/900W
2000VA/1800W
3000VA/2700W
INPUT
Voltage range
110~300VAC depends on load level
Frequency range
45-55Hz / 54-66Hz
Phase
Single phase with ground
THDI
< 5% with full load
Power factor
≥ 0.99
OUTPUT
Voltage
200/208/220/230/240VAC
Voltage regulation
± 2%
Frequency
45-55Hz / 54-66Hz (synchronized range)
Frequency (bat mode)
50Hz / 60Hz ± 0.2Hz
Current crest ratio
3:1
Harmonic distortion
< 3% @ Linear Load
< 5% Non-Linear Load
Output waveform
Pure Sine Wave
Overload capacity
1min@105% - 110% load
30s@110% - 120% load
10s@125% - 150%
1s@ > 150% load
EFFICIENCY
Line mode
> 87%
> 88%
BAT mode
> 85%
Eco mode
> 94%
BATTERY
Number of batteries
Depending on the capacity of external batteries
Battery type
Backup time
Recharge time
Charging current
8A
8A / Adjustable or optional (optional: +4A = 12A)
TRANSFER TIME
BAT ↔ LINE
0ms
INV ↔ BYPASS
< 4ms
INV → ECO
< 4ms
ECO → INV
< 10ms
INDICATOR
LCD
Load / Battery / Input / Output / Operating Mode Information
AUDIBLE ALARM 
BAT mode
Sounding every 4 seconds
Battery low
Sounding every second
Fault
Continuously sounding
Overload capacity 
Sounding twice every second
GENERAL
Operation environment
0 - 45°C
Relative humidity
20 - 90% (non-condensing)
Acoustic noise
< 50dB @ front 1 meter
Tower case (HxWxD)
220x145x400
347x192x460
INTERFACE
USB
Software supports Windows Family, Linux, Sun Solaris, MAC
External slot
SNMP/AS400/Relay Card
EPO
Emergency Power Off